ES2400 – ES2403 – ES4800 - ES6000
User's Manual
___________________________________________________________________________________________________________________________________________________
MANUAL CHARGE TERMINATION
While the charge is in progress, it's possible to turn off the charger by pressing the red button
“STOP”. The MRG front panel will show the message “MANUAL STOP”.
In this condition, it's safe to disconnect the battery.
EQUALIZATION
The EagleSmart chargers Equalize the battery on a weekly basis. The operation is totally
automatic.
After the normal completion of the charge, the EagleSmart chargers wait for 15 hours, then it
gives 4 equalization cycles of 30 minutes, with 15 hours of interval between each cycle.
While the equalization charge is in progress, the MRG Front Panel shows the message
“EQUALIZING”:
With this timing system, the equalization is performed only in the weekend, when the battery
remains connected to the charger for more than 15 hours after the completion of the charge.
At the end of the equalization, the charger will remain in stand-by mode, while the front panel
gives the message “COMPLETE”:
__________________________________________________________________________________________________________________________________________________
Page 12/14
Komentarze do niniejszej Instrukcji