Alarm Lock PL6100 Instrukcja Obsługi Strona 9

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 8
9
Erase All Programming
Restore the "out of box" factory condition.
1. At the back of the lock, remove the lock housing screw and remove the cover.
2. Take out battery pack and remove battery power by disconnecting the battery pack plug.
3. With battery power disconnected, short the two white wires (Remote Input wires) together for 10
seconds to ensure discharge of all capacitors. After 10 seconds, remove the short.
4. Plug in the (provided) male shunt connector into the yellow wire female connector.
5. With shunt connector connected, re-connect the battery pack. The lock will immediately sound 3
short beeps (if these 3 beeps are not heard, then restart at step 3).
6. The lock will then sound more slow beeps, 1 beep for every second it takes to clear the memory.
7. Lock is ready for programming after 2 rapid beeps are heard and 2 green LED flashes are seen.
Verifying Proximity Card and Keyfob Access
Test by simply presenting a valid proximity card or fob to the reader in front of the lock.
VALID CARD - Green LED flashes, the sounder beeps several times and the PL6100 unlocks.
INVALID CARD - Red LED flashes several times and the sounder beeps several times.
Testing the Cards Entered
Use when re-applying power to a lock already in use (you wish to retain the Lock Program), such as when
moving an existing lock to a new door. The lock must be dismantled and powered down for an extended
period.
1. Disconnect battery pack connector.
2. With battery power disconnected, short the two white wires (Remote Input wires) together for 10
seconds to ensure discharge of all capacitors.
3. Re-connect battery pack (lock will sound 3 short beeps). If these 3 beeps are not heard, then restart
at step 1. The lock will perform several self tests; when complete, 7 beeps and LED flashes will
sound. The lock is now ready for use.
Power Up--Retain Existing Programming
ACTIVITY LED SOUNDER COMMENTS
Access Granted or
Remote Release
2 Green Flashes 2 Beeps
Invalid Card 7 Red Flashes 7 Beeps An invalid card does not exist in the Lock Program memory.
Valid but disabled card
1 Green, 4 Red
Flashes
1 Long, 5 Short Beeps A proximity card exists in memory, but is disabled.
Low Battery
Red Flashes for
Four Seconds
4-Second Pulsing Beep
See "Battery Replacement" on page 8.
Emergency Commands
are in effect
1 Red Flash every
two seconds
LED and Sounder Indicators
With a fully charged battery, the LED and sounder provide visual and audible feedback as follows: