ACTIVITY LED SOUNDER COMMENTS
Keypress 1 RED Flash 1 Beep Normal Operation
Access Granted 3 GREEN Flashes 3 Beeps
Invalid Code 6 RED Flashes 6 Beeps Re-enter User Code
Successful Program Entry 2 GREEN Flashes 2 Beeps When in Program Mode
Unsuccessful Program Entry 7 RED Flashes 7 Beeps When in Program Mode
Exit Program Mode Flashes: 1 Red, 2 Green,
then 1 Red
10 Beeps "73" in Continuous Wave
(Morse Code)
Valid but Disabled Code 1 Green, 4 Red Flashes 1 long, 5 short beeps Code exists in memory, but disabled
Low Battery Yellow Flash during key
presses
Long Beep See page 11 before changing batteries
User Code Entered Yellow Flash Sequence of 7 Beeps
Repeated 4 Times
Non-fatal memory or clock error has been
detected. Under this condition,
unexpected operation is possible. Re-
move power and restart.
Inside Lever Depressed and held down 7 Red Flashes, 1 Red Flash 7 Beeps. 1 Beep Example: Inside lever not released for 5
seconds after User Code access granted.
Outside Lever Depressed and held down 7 Red Flashes, 2 Red
Flashes
7 Beeps. 2 Beeps Example. Outside lever depressed for 5
seconds after User Code access denied.
Deadbolt Engaged / Button Pressed and
button held down
7 Red Flashes, 3 Red
Flashes
7 Beeps. 3 Beeps Example: Valid User Code entered while
Deadbolt extended.
Programming Key Sequence
.
Programming
Information
General Program Mode Information
If a wrong key is pressed during code entry, hold any key continuously until the error sound is heard (7 short beeps), this will clear the entry. Re-enter the key
sequence again.
All program sequences are followed by the
:
key; 2 short beeps indicate a successful program sequence.
Enabling/Disabling Users (By User Number)
3. Disable User
;
3
;
[ _ _ _ ]
:
4. Enable User
;
4
;
[ _ _ _ ]
:
User Number must be between 2 and 2000.
NOTE: Will Enable/Disable users even if the user is associated with an enabled group.
2
Conventions Used in this Manual
LED and Sounder Indicators
The DL Series locks provide visual and audible keypad feedback. With a fully charged battery, the LED and sounder feedback
is as follows:
Minimum Required Program Level
Program Levels are abbreviated as follows:
M
= Master
4
= Installer
3
= Manager
2
= Supervisor
1
= Print Only Users
This Program Level abbreviation is the
minimum
program level required to
access the particular Function. (The
higher the level, the more programming
tasks the User is allowed, with
Master
allowing all tasks).
Function
Description
Function
Number
Function Name