DL-Windows Programmable Functions
"Programmable Features" Screen - Relay Functions tab
Select any of the relay functions below to activate the
integral relay output (more than one may be selected).
Remote Input While Enabled
Activates relay when the Remote Input (two white wires
inside the rear housing) are momentarily shorted.
Provides an alert that access has been granted via the
Remote Input.
Remote Input While Disabled
Activates relay when the Remote Input wires (two white
wires inside the rear housing) are momentarily shorted
when the Remote Input is disabled. Provides an alert
that an unsuccessful access has been attempted via the
Remote Input.
Failed Entry Attempt
Activates relay if any unsuccessful proximity card entry
attempt occurs. Provides an alert that an unauthorized
proximity card entry attempt has been detected.
Disabled User Entered Code
Activates relay if a User presents their proximity card
while that proximity card is disabled. Provides an alert
that a disabled proximity card entry attempt has been
detected.
Authorized Entry
Activates relay anytime a User presents a valid
proximity card and is granted access.
Scheduled (Group 1 Activated)
Activates relay if the PL6100 has been programmed for
"Scheduled Relay Activation (Group 1 Initiated)" and a
member of Group 1 has presented their proximity card
within the required window.
Locked by Schedule
Activates relay if the PL6100 has been locked by a
programmed schedule.
Unlocked by Schedule
Activates relay if the PL6100 has been unlocked by a
programmed schedule.
Lockout # of Attempts Exceeded
Activates relay if the number of proximity card entry at-
tempts has been exceeded and the PL6100 enters
"lockout mode" (where it will refuse to recognize ANY
proximity card presentations).
Any Card Entry
Activates relay any time a proximity card is presented.
Relay follows Lock/Unlock Status
Activates relay when the PL6100 is unlocked. Relay
power must be provided from an external power supply.
If this option is selected, the relay remains activated as
long as the PL6100 is unlocked. This feature super-
sedes all other relay options.