21
; 6 0 ; [ _ ] :
(Number of Attempts)
60. Number of Attempts Before Keypad Lockout
61. Set the Attempts Keypad Lockout Time
Number of attempts before the keypad is locked-out must be 1-9 attempts.
The number of attempts is reduced by half every time the keypad is locked-out without a successful code entry (default is 6 attempts).
The attempt count is reset each time a valid code is entered.
Note: In Two Door Mode, "Keypad Lockout" only applies to the individual keypad responsible. See WI1856 for more information.
Keypad Lockout Time must be 1-60 seconds.
Program the length of time the keypad is locked-out after a series of unsuccessful attempts (default is 18 seconds).
Note: In Two Door Mode, "Keypad Lockout" only applies to the individual keypad responsible. See WI1856 for more information.
4
4
KEYPAD LOCKOUT
; 6 4 :
64. Disable Remote Input
Wire a Normally Open Contact to NETWORXPANEL terminals T26 & T27. Momentarily close switch to unlock door to allow pas-
sage. Enter the functions below to Disable/Enable the Remote Input. NOTE: The Remote Input is enabled by default.
Remote Input
; 6 5 :
65. Enable Remote Input
; 6 6 ; [ _ _ ] :
(Ambush Code)
66. Ambush Code
Ambush code must be 2 digits.
An error sounds if Ambush Code matches the 1st two digits of any User Code. See Function 67 for more information.
2
3
REMOTE INPUT
AMBUSH
; 6 1 ; [ _ _ ] :
(Keypad Lockout Time)
Programming Functions (cont'd)
;62 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] :
(User Number) (User Code)
62. Add/Delete/Change User Codes 2-5000
(for Primary Keypad Code Entry)
User Number must be between 2 and 5000. User Codes entered are enabled for use with the Primary keypad only.
To delete a code, leave the User Code blank and wait for the rapid beeping to stop, then press and hold : for three seconds to
exit Programming Mode. If more programming is desired, re-enter Programming Mode.
User Code must be 3-6 digits.
Each User Code can be thought of as a person. As long as each person possesses their own unique User Code, you can control
access to the lock by adding or deleting User Codes. See "Terminology Used in this Manual" on page 6 for more information.
3
;63 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] :
(User Number) (User Code)
63. Add/Delete/Change User Codes 2-5000
(for Secondary Keypad Code Entry)
Same as Function 62, except User Codes entered are enabled for use with the Secondary keypad only.