60. Number of Attempt Before Lockout
61. Set the Attempts Lockout Time
•
Number of attempts before lockout must be 1-9 attempts.
•
The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
•
The attempt count is reset each time a valid code is entered.
•
Lockout Time must be 1-60 seconds.
How long the keypad is locked out after a series of unsuccessful attempts (default is 15
seconds).
4
4
LOCKOUT
; 6 4 :
64. Disable Remote Input
•
Wire a Normally Open Contact to Terminals 3 & 4. Momentarily close to allow person to
pass through door.
•
Enter the functions below to Disable/Enable the Remote Input.
NOTE: The Remote Input is enabled as part of the default program.
Remote Input Disable/Enable
; 6 5 :
65. Enable Remote Input
66. Reserved
2
REMOTE INPUT
; 6 0 ;
[ _ ]
:
(Number of Attempts)
; 6 1 ; [ _ _ ] :
(Lockout Time)
62-63. Reserved
59. AL-DTM Door Number
•
Door Number must be between 1- 96.
For use with Alarm Lock’s AL-DTM Data Transfer Module. Using the AL-DTM up to 48
locks (96 for AL-DTM2) can be Downloaded/Uploaded and History LOGs can be
retrieved. Enter a door number for each lock. After configuring the AL-DTM, using
Alarm Lock's DL-WINDOWS Software, any of the following data transfers can be
initiated by plugging the AL-DTM into the lock and simply entering User Code 299 at the
lock.
•
Upload Lock Program
•
Upload History LOG
•
Download Lock Program
4
AL-DTM
; 5 9 ;
[ _ _ ]
:
Door Number)