5
Programmable Timeout Functions
Timeout functions allow enabling/disabling users and
enabling passage mode for a time period without requiring
the user to return to the lock.
Users Associated for more than one group
Note: If a user is associated with more than one group, all
associated groups would have to be disabled before the
user is disabled.
Service Code
User number 300 is the service code. Once the service
code is used, it is disabled. Function 9 is used to re-enable
the service code.
Keypad Lockout
Programmable number of attempts before keypad lockout.
Programmable lockout time.
Non-Volatile Memory
All programming is stored in non-volatile memory.
Error Checking
Extensive keypad program error checking reduces likelihood
of programming error.
Real Time Clock
Real time clock allows logging of events to within one second
accuracy. Unique feature (Functions 43/44) allows speeding
up or slowing down the clock providing long term accuracy of
the clock functions to within 3 minutes per year.
Group 1 Member puts lock in Passage Mode
Feature (88 & 89)
Lock remains locked—until Group 1 manager arrives.
1.
Use Function 88 to set an Open Time Window. The
lock will unlock (Passage Mode) when any Group 1
Member enters a code.
2.
Use Function 89 to set the time to close the window.
Note:
Passage Mode will have to be disabled each
night using Function 46 or schedule Function 73.
Example:
Open window at 7:00AM using function 88,
Close Window at 8:30AM using function 89.
Lock will unlock when a member of group 1 enters their
code between 7:00AM and 8:30AM. If no group 1
member arrives between 7:00AM and 8:30AM, the lock
will stay locked all day.
Group 1 Member Enables Group 4 Users (92
& 93)
This feature requires Group 4 users to wait outside
until a Group 1 manager arrives to enable their codes.
1.
Use Function 92 to set the time to open the window
allowing any group 1 member to enable group 4.
2.
Use Function 93 to set the time to close the window.
Note:
Group 4 will have to be disabled each night using
Function 17 or schedule Function 82.
Example:
Open
window at 7:00AM using Function 92, close window at
8:30AM using Function 93.Group 4 will be enabled when
a member of group 1 enters their code between 7:00AM
and 8:30AM (group 4 users will have to wait outside until
a manager arrives to enable their codes. If a manager
does not arrive between 7:00AM and 8:30AM, group 4 is
not enabled.
Komentarze do niniejszej Instrukcji